Figure 1-8: The Sampling Mode Menu. |
The options are:
Vy == Ey | Samples the voltage Vy in the TLM mesh. |
Iz == - Hx | Samples the z-component of the mesh current in the TLM mesh. |
Ix == Hz | Samples the x-component of the mesh current in the TLM mesh. |
Izx == Hxz | Samples the magnitude of the vector sum of Iz and Ix in the TLM mesh. |
P(V)=sigma*Vy*Vy | Samples the quantity s(Vy)2 in the TLM mesh. |
P(I)=sigma*Izx*Izx | Samples the quantity s (IZX) 2 in the TLM mesh. |
The next four modes are the Johns
Matrix (Section 4.3 of the "MEFiSTo-2D Theory" booklet)
generation modes in which impulses emerging from the
sampling point are stored. They are:
Top-Bound Impulse | Samples the impulse traveling from the probe towards the TOP. |
Left-Bound Impulse | Samples the impulse traveling from the probe towards the LEFT |
Bottom-Bound Impulse | Samples the impulse traveling from the probe towards the BOTTOM |
Right-Bound Impulse | Samples the impulse traveling from the probe towards the RIGHT |